X-Ray Radiation Dose Report

(observed: 2024-08-01 15:42:18)

Concept Modifier: Procedure reported [Annex 1]
Observation Context: Observer Type: = Device (121007, DCM)
Observation Context: Device Observer UID: = 1.2.840.113619.6.491
Observation Context: Device Observer Name: = "AGGRCCT01"
Observation Context: Device Observer Manufacturer: = "GE Medical Systems"
Observation Context: Device Observer Model Name: = "Revolution EVO"
Observation Context: Device Observer Serial Number: = "*"
Observation Context: Device Role in Procedure: = Irradiating Device (113859, DCM)
Observation Context: Device Role in Procedure: = Recording (121097, DCM)
Observation Context: Start of X-Ray Irradiation: = 2024-08-01 15:37:52
Observation Context: End of X-Ray Irradiation: = 2024-08-01 15:42:18
Observation Context: Scope of Accumulation [Annex 2]

CT Accumulated Dose Data

3 {events} 186.97 mGy.cm

CT Acquisition

6.1 Abdomen/Pelvis C+ Abdomen Constant Angle Acquisition 1.2.840.113619.2.491.3.363608172.745.1722488299.131

CT Acquisition Parameters

2.34 s 419.27 mm 65.09 mm -354.18 mm 1.2.840.113619.2.491.3.363608172.745.1722488299.129.17490.5 1.25 mm 419.27 mm 1 {X-Ray sources}

CT X-Ray Source Parameters

1 120.0 kV 10.0 mA 10.0 mA

CT Acquisition

6.1 Abdomen/Pelvis C+ Abdomen Constant Angle Acquisition 1.2.840.113619.2.491.3.363608172.745.1722488299.133

CT Acquisition Parameters

2.34 s 419.27 mm 65.09 mm -354.18 mm 1.2.840.113619.2.491.3.363608172.745.1722488299.129.17490.5 1.25 mm 419.27 mm 1 {X-Ray sources}

CT X-Ray Source Parameters

1 120.0 kV 10.0 mA 10.0 mA

CT Acquisition

6.1 Abdomen/Pelvis C+ Abdomen Spiral Acquisition 1.2.840.113619.2.491.3.363608172.745.1722488299.218

CT Acquisition Parameters

5.32 s 338.64 mm 303.75 mm 349.32 mm 47.38 mm -256.38 mm 65.13 mm -273.51 mm 1.2.840.113619.2.491.3.363608172.745.1722488299.129.17490.5 0.62 mm 40.0 mm 0.98 {ratio} 1 {X-Ray sources}

CT X-Ray Source Parameters

1 120.0 kV 400.0 mA 104.0 mA 0.6 s

CT Dose

5.52 mGy IEC Body Dosimetry Phantom 186.97 mGy.cm

Dose Check Alert Details

No Yes 1000.0 mGy

Dose Check Notification Details

No Yes 50.0 mGy

Source of Dose Information: Automated Data Collection (113856, DCM)

Annex

Annex 1

Procedure reported: Computed Tomography X-Ray (P5-08000, SRT)

Concept Modifier: Has Intent: = Diagnostic Intent (R-408C3, SRT)

Annex 2

Scope of Accumulation: Study (113014, DCM)

Properties: Study Instance UID: = 1.2.840.113619.2.491.3.363608172.745.1722488299.128