Results
Patient: |
MARIA LICHT |
MRN: |
AG0001141103 |
Accession: |
154682748 |
Sex: |
Female |
Date of Exam: |
2024-08-01
|
Physician: |
KIM M HEIM |
08-01-2024
15:37:52
X-Ray Radiation Dose Report
(observed: 2024-08-01 15:42:18)
Concept Modifier: Procedure reported [Annex 1]
Observation Context:
Observer Type:
= Device (121007, DCM)
Observation Context:
Device Observer UID:
= 1.2.840.113619.6.491
Observation Context:
Device Observer Name:
= "AGGRCCT01"
Observation Context:
Device Observer Manufacturer:
= "GE Medical Systems"
Observation Context:
Device Observer Model Name:
= "Revolution EVO"
Observation Context:
Device Observer Serial Number:
= "*"
Observation Context:
Device Role in Procedure:
= Irradiating Device (113859, DCM)
Observation Context:
Device Role in Procedure:
= Recording (121097, DCM)
Observation Context:
Start of X-Ray Irradiation:
= 2024-08-01 15:37:52
Observation Context:
End of X-Ray Irradiation:
= 2024-08-01 15:42:18
Observation Context: Scope of Accumulation [Annex 2]
CT Accumulated Dose Data
3 {events}
186.97 mGy.cm
CT Acquisition
6.1 Abdomen/Pelvis C+
Abdomen
Constant Angle Acquisition
1.2.840.113619.2.491.3.363608172.745.1722488299.131
CT Acquisition Parameters
2.34 s
419.27 mm
65.09 mm
-354.18 mm
1.2.840.113619.2.491.3.363608172.745.1722488299.129.17490.5
1.25 mm
419.27 mm
1 {X-Ray sources}
CT X-Ray Source Parameters
1
120.0 kV
10.0 mA
10.0 mA
CT Acquisition
6.1 Abdomen/Pelvis C+
Abdomen
Constant Angle Acquisition
1.2.840.113619.2.491.3.363608172.745.1722488299.133
CT Acquisition Parameters
2.34 s
419.27 mm
65.09 mm
-354.18 mm
1.2.840.113619.2.491.3.363608172.745.1722488299.129.17490.5
1.25 mm
419.27 mm
1 {X-Ray sources}
CT X-Ray Source Parameters
1
120.0 kV
10.0 mA
10.0 mA
CT Acquisition
6.1 Abdomen/Pelvis C+
Abdomen
Spiral Acquisition
1.2.840.113619.2.491.3.363608172.745.1722488299.218
CT Acquisition Parameters
5.32 s
338.64 mm
303.75 mm
349.32 mm
47.38 mm
-256.38 mm
65.13 mm
-273.51 mm
1.2.840.113619.2.491.3.363608172.745.1722488299.129.17490.5
0.62 mm
40.0 mm
0.98 {ratio}
1 {X-Ray sources}
CT X-Ray Source Parameters
1
120.0 kV
400.0 mA
104.0 mA
0.6 s
CT Dose
5.52 mGy
IEC Body Dosimetry Phantom
186.97 mGy.cm
Dose Check Alert Details
No
Yes
1000.0 mGy
Dose Check Notification Details
No
Yes
50.0 mGy
Source of Dose Information:
Automated Data Collection (113856, DCM)
Annex
Procedure reported:
Computed Tomography X-Ray (P5-08000, SRT)
Concept Modifier:
Has Intent:
= Diagnostic Intent (R-408C3, SRT)
Scope of Accumulation:
Study (113014, DCM)
Properties:
Study Instance UID:
= 1.2.840.113619.2.491.3.363608172.745.1722488299.128