X-Ray Radiation Dose Report
(observed: 2024-08-15 23:24:55)
Concept Modifier: Procedure reported [Annex 1]
Observation Context:
Observer Type:
= Device (121007, DCM)
Observation Context:
Device Observer UID:
= 1.2.840.113619.6.491
Observation Context:
Device Observer Name:
= "AGGRCCT01"
Observation Context:
Device Observer Manufacturer:
= "GE Medical Systems"
Observation Context:
Device Observer Model Name:
= "Revolution EVO"
Observation Context:
Device Observer Serial Number:
= "*"
Observation Context:
Device Role in Procedure:
= Irradiating Device (113859, DCM)
Observation Context:
Device Role in Procedure:
= Recording (121097, DCM)
Observation Context:
Start of X-Ray Irradiation:
= 2024-08-15 23:20:39
Observation Context:
End of X-Ray Irradiation:
= 2024-08-15 23:24:55
Observation Context: Scope of Accumulation [Annex 2]
CT Accumulated Dose Data
3 {events}
323.6 mGy.cm
CT Acquisition
6.1 Abdomen/Pelvis C+
Abdomen
Constant Angle Acquisition
1.2.840.113619.2.491.3.363608172.641.1723697789.95
CT Acquisition Parameters
3.2 s
569.27 mm
65.09 mm
-504.18 mm
1.2.840.113619.2.491.3.363608172.641.1723697789.93.19700.5
1.25 mm
569.27 mm
1 {X-Ray sources}
CT X-Ray Source Parameters
1
120.0 kV
10.0 mA
10.0 mA
CT Acquisition
6.1 Abdomen/Pelvis C+
Abdomen
Constant Angle Acquisition
1.2.840.113619.2.491.3.363608172.641.1723697789.99
CT Acquisition Parameters
3.54 s
629.27 mm
125.09 mm
-504.18 mm
1.2.840.113619.2.491.3.363608172.641.1723697789.93.19700.5
1.25 mm
629.27 mm
1 {X-Ray sources}
CT X-Ray Source Parameters
1
120.0 kV
10.0 mA
10.0 mA
CT Acquisition
6.1 Abdomen/Pelvis C+
Abdomen
Spiral Acquisition
1.2.840.113619.2.491.3.363608172.641.1723697789.102
CT Acquisition Parameters
8.64 s
556.14 mm
521.25 mm
566.82 mm
118.12 mm
-403.12 mm
135.88 mm
-420.26 mm
1.2.840.113619.2.491.3.363608172.641.1723697789.93.19700.5
0.62 mm
40.0 mm
0.98 {ratio}
1 {X-Ray sources}
CT X-Ray Source Parameters
1
120.0 kV
400.0 mA
109.6 mA
0.6 s
CT Dose
5.82 mGy
IEC Body Dosimetry Phantom
323.6 mGy.cm
Dose Check Alert Details
No
Yes
1000.0 mGy
Dose Check Notification Details
No
Yes
50.0 mGy
Source of Dose Information:
Automated Data Collection (113856, DCM)
Annex
Procedure reported:
Computed Tomography X-Ray (P5-08000, SRT)
Concept Modifier:
Has Intent:
= Diagnostic Intent (R-408C3, SRT)
Scope of Accumulation:
Study (113014, DCM)
Properties:
Study Instance UID:
= 1.2.840.113619.2.491.3.363608172.641.1723697789.92